Zhao Lifan, Tang Hongbing, Wu Ying, Cao Yi, Jin Yi. Determination of Aluminum in Flour Products by ICP-MS[J]. Journal of Environmental Hygiene, 2013, 3(3): 245-247.
    Citation: Zhao Lifan, Tang Hongbing, Wu Ying, Cao Yi, Jin Yi. Determination of Aluminum in Flour Products by ICP-MS[J]. Journal of Environmental Hygiene, 2013, 3(3): 245-247.

    Determination of Aluminum in Flour Products by ICP-MS

    • Objectives To establish a method for the determination of aluminum in flour food by inductively coupled plasma mass spectrometry (ICP-MS), to explore the main sources of interference, and monitor the concentration of aluminum in flour food.
      Methods After microwave digestion, the samples were detected for the content of aluminum by ICP/MS in the condition of 45Sc as the internal standard for eliminating matrix effect.
      Results The detection limit of aluminum was 0.03 mg/kg. Recovery rates of spiked samples range from 92.0% to 106.0%, and RSD was 2.15%~3.45%.
      Conclusions This method has low detection limit, broad linear range with simple operation and quick analysis. It can be used for determining aluminum in flour food.
    • loading

    Catalog

      Turn off MathJax
      Article Contents

      /

      DownLoad:  Full-Size Img  PowerPoint
      Return
      Return