翟文慧, 王爱月, 李永利, 田好亮. 河南省餐饮单位生活饮用水微生物污染状况调查[J]. 环境卫生学杂志, 2014, 4(2): 171-173, 177.
    引用本文: 翟文慧, 王爱月, 李永利, 田好亮. 河南省餐饮单位生活饮用水微生物污染状况调查[J]. 环境卫生学杂志, 2014, 4(2): 171-173, 177.
    Zhai Wenhui, Wang Aiyue, Li Yongli, Tian Haoliang. Quality of Drinking Water in Catering Units in Henan Province[J]. Journal of Environmental Hygiene, 2014, 4(2): 171-173, 177.
    Citation: Zhai Wenhui, Wang Aiyue, Li Yongli, Tian Haoliang. Quality of Drinking Water in Catering Units in Henan Province[J]. Journal of Environmental Hygiene, 2014, 4(2): 171-173, 177.

    河南省餐饮单位生活饮用水微生物污染状况调查

    Quality of Drinking Water in Catering Units in Henan Province

    • 摘要:
      目的 了解河南省餐饮单位生活饮用水微生物污染状况, 为监管部门提供有效的监管依据。
      方法 抽检全省各地市、县的宾馆酒店、中小型饭店、学校及幼儿园餐厅的生活饮用水278份, 依据生活饮用水标准检验方法(GB/T 5750-2006)1测定菌落总数、总大肠菌群、耐热大肠菌群、大肠埃希菌4项微生物指标。
      结果 278份水样综合合格率为68.3%, 菌落总数、总大肠菌群、耐热大肠菌群、大肠埃希菌合格率分别为73.7%、76.6%、82.4%和92.1%;市区和县区餐饮单位生活饮用水综合合格率分别为74.6%和50.7%, 差异有统计学意义(χ2=14.27, P<0.01);集中式供水、二次供水和分散式供水合格率分别为71.1%、88.7%和10.7%, 差异有统计学意义(χ2=53.79, P<0.01);宾馆酒店、中小型饭店、学校及幼儿园餐厅生活饮用水合格率分别为88.9%、57.8%、62.5%和65.4%, 差异有统计学意义(χ2=19.91, P < 0.01)。
      结论 河南省餐饮单位生活饮用水微生物指标合格率偏低, 分散式供水餐饮单位微生物污染尤为严重。

       

      Abstract:
      Objectives To learn the current hygienic situation of drinking water in catering units of Henan province and to provide corresponding basis for supervision departments.
      Methods Drinking water samples were collected randomly from hotels, small and medium sized restaurants, school and kindergarten canteens all over the province, and the counts of total bacteria, coliforms, thermo-tolerant coliforms and E.coli were examined in 278 samples according to the Standard Examination Methods for Drinking Water (GB/T 5750-2006).
      Results The comprehensive qualification rate of 278 samples was 68.3%, the qualification rates for total bacterial counts, coliforms, thermo-tolerant coliforms and E. coli in these samples were 73.7%, 76.6%, 82.4% and 92.1%, respectively. Qualification rates of the drinking water in catering units in cities and counties were 74.6% and 50.7%, (χ2=14.27, P < 0.01);qualification rates of centralized, secondary and de-centralized water supplies were 71.1%, 88.7% and 10.7%, respectively (χ2=53.79, P < 0.01);qualification rates of water supplies in hotels, small and medium sized restaurants, school and kindergarten canteens were 88.9%, 57.8%, 62.5% and 65.4%, respectively (χ2=19.91, P < 0.01).
      Conclusions The major problem of drinking water in catering units of Henan province was microbial contamination. The contamination was particularly serious in de-centralized water supplies.

       

    /

    返回文章
    返回