钟敏, 刘成刚. 2015—2016年石河子市医疗机构消毒效果监测分析[J]. 环境卫生学杂志, 2019, 9(4): 361-364. DOI: 10.13421/j.cnki.hjwsxzz.2019.04.011
    引用本文: 钟敏, 刘成刚. 2015—2016年石河子市医疗机构消毒效果监测分析[J]. 环境卫生学杂志, 2019, 9(4): 361-364. DOI: 10.13421/j.cnki.hjwsxzz.2019.04.011
    ZHONG Min, LIU Chenggang. Monitoring and Analysis of Disinfection Effects in Medical Institutions in Shihezi from 2015 to 2016[J]. Journal of Environmental Hygiene, 2019, 9(4): 361-364. DOI: 10.13421/j.cnki.hjwsxzz.2019.04.011
    Citation: ZHONG Min, LIU Chenggang. Monitoring and Analysis of Disinfection Effects in Medical Institutions in Shihezi from 2015 to 2016[J]. Journal of Environmental Hygiene, 2019, 9(4): 361-364. DOI: 10.13421/j.cnki.hjwsxzz.2019.04.011

    2015—2016年石河子市医疗机构消毒效果监测分析

    Monitoring and Analysis of Disinfection Effects in Medical Institutions in Shihezi from 2015 to 2016

    • 摘要:
      目的 了解新疆生产建设兵团石河子市医疗机构消毒状况,为医疗机构消毒管理工作提供科学依据。
      方法 采用现场抽样和微生物检验的方法,对石河子市各级医疗机构开展消毒效果监测与评价。
      结果 共检测样品1 207份,合格数为1 131份,合格率为93.70%,其中2016年消毒合格率为91.57%(456/498),低于2015年的95.20%(675/709),差异有统计学意义(χ2=6.563,P < 0.05)。不同项目中,空气的消毒合格率最高,为96.43%(27/28);治疗用水的消毒合格率最低,为75.68%(28/37)。不同类别医疗机构比较,诊所的消毒合格率最低,为88.83%(326/367),差异有统计学意义(χ2=21.310,P < 0.05)。
      结论 石河子市医疗机构治疗用水的消毒合格率偏低,要重点对诊所进行监管,提高消毒管理水平。

       

      Abstract:
      Objectives To understand the disinfection status of medical institutions in Shihezi city of Xinjiang Production and Construction Corps, and to provide scientific basis for the disinfection management of medical institutions.
      Methods The on-site sampling and microbiological testing method were used to monitor and evaluate the disinfection effects of medical institutions at all levels in Shihezi.
      Results A total of 1 207 samples were tested. The number of qualified was 1 131, and the qualified rate was 93.70%. The disinfection rate in 2016 (91.57%) was lower than that in 2015 (95.20%), and the difference was statistically significant (χ2=6.563, P < 0.05). Among the different projects, the highest rate of air disinfection was 96.43%. The disinfection rate of treatment water was the lowest at 75.68%. Compared with different types of medical institutions, the disinfection rate of clinics was the lowest, which was 88.83%, and the difference was statistically significant (χ2=21.310, P < 0.05).
      Conclusions The qualified rate of disinfection of therapeutic water in medical institutions of Shihezi city was low. Future management should focus on the supervision of clinics and the improvement of disinfection management.

       

    /